In addition a check could be made of the history of loan equipment and how much information the loan company provide and require on the return of the.
If the disinfectant is produced locally from a CE- marked generator, a copy of the CE certificate should be available. Regular checks on areas of non-compliance. This list can form the basis for action, with date lines, to correct the problems or highlight them to other authorities.
It is important that. Commission CQC or equivalent regulatory body may regularly request copies of the non- compliance forms enabling them to check the timescale of highlighted improvements. Are weekly TVC checks carried out? Are quarterly tests carried out? Are the quarterly tests satisfactory? Are annual tests carried out? Are the annual test results satisfactory?
Is there an EWD logbook available in the unit? Note : Site visit s are required by the supplier to ensure that the machine s will fit correctly and that no problems will be encountered during the delivery process. All engineering systems and services should be surveyed during the visit s. Requirements and tests for washer-disinfectors employing chemical disinfection for thermolabile endoscopes.
Medical devices. Quality managements systems. Requirements for regu- latory purposes. BS EN Safety requirements for electrical equipment for measurement, control and laboratory use. Particular requirements for sterilizers and washer-disinfectors used to treat medical materials. Sterilization of medical devices. Information to be provided by the manu- facturer for the processing of resterilizable medical devices. Scope connectors and accessories: these can incur additional costs and should be considered thoroughly during the procurement process.
Consideration should be given to the reprocessing of endoscopes that may have a typical lumen configuration. Good weather covering to protect machines under delivery - B Dust-proof packing and wrapping for further storage needs - C Dust-proof packing and timber casing - D.
These connections will then be clearly illustrated on the drawings as submitted with the tender. Select one or more:. Medium choice will affect the cycle time. The supplier should discuss the options available and services required with the User. Water treatment Required yes or no Comments and details Filtration requirements. Testing and maintenance contracts are to be quoted by the manufacturer during the tender for the costs to be analysed by the User for machine care after the warranty period.
This will include drawings for consultation. TVC, conductivity, hardness etc. Are there any specific installa- tion problems complying with local water acts or regula- tions? What is the supply pressure range required for the EWDs? Can this be achieved by the chosen water supply? This section is a guide for the type of information and energy duties that is required by the User for a good and effective installation. Details of interface and file protocol requirements for transfer of data in the storage device to an external computer.
Details of diagnostic checks incorporated in the system. Details including cost of the data storage device. Maximum ambient temperature within the protective case Suppliers are required to advise of the storage conditions required if different from final installed.
Audit of flexible-endoscope decontamination In document Health Technical Memorandum Decontamination of flexible endoscopes. Part C: Operational management Page Summary for commissioners and quality inspectors The purpose of audit is discussed and the guides that can be used to carry out the exercise.
Audit is limited to the information at its disposal, but the aim is to confirm systems are in place to provide endoscopes safe for next patient use, being clean and free of biological contamination. Internal audit — decontamination 6. Every year over , patients in England acquire a healthcare associated infection whilstin hospital.
Medical Audits provide advice, support, training, consultancy and auditing services to Acute hospitals, Nursing homes, Hospices, Residential care settings and other Healthcare providers so they can continue to provide and maintain a safe environment for their clients and residents during the COVID Pandemic. Flexible endoscopes have been associated with more hospital acquired infections than any other device Spach et al, and require unique decontamination considerations due to their design.
Their external surfaces and internal channels for air, water, aspiration and accessories are all potentially exposed to body fluids and other contaminants. They are also heat labile and so cannot be autoclaved. These must go through a process of sterilisation rather than high level disinfection.
Endoscope decontamination is a specialist process and needs to be carried out in a designated Endoscopy Unit. This audit is designed and developed to assist you in assuring you meet the relevant standards and guidelines and identify areas for intervention. Guidelines on the management of endoscopes have been updated on many occasions since they were first published in This audit was designed with reference to the most up to date NHS guidelines and has been prepared with reference to Using Medical Audits Decontamination Audit system you can audit practice against the most up to date NHS decontamination standards and HSE decontamination code of practice as well as best practice guidelines for Infection Prevention and control in endoscopy units.
The decontamination audit system has been designed to assist identification of risks and training requirements, assess practice in relation to safe management of reusable invasive medical devices and evidence your compliance with relevant endoscopy unit standards. Environmental Hygiene Audit Tools.
Environment Audits Linen Audits. Equipment Audits Sharps Audits.